BOLD Industrial
Fluke 375 True RMS AC/DC Clamp Meter
Couldn't load pickup availability
Fluke 375 True‑RMS AC/DC Clamp Meter – Specifications
⚡ Electrical Measurements
-
AC Current (via fixed jaw):
• Range: up to 600.0 A
• Resolution: 0.1 A
• Accuracy: ±2% ±5 digits (10–100 Hz); ±2.5% ±5 digits (100–500 Hz)
• Crest Factor: up to 3 at 500 A, 2.5 at 600 A; add 2% for crest factor >2 -
AC Current (via optional iFlex probe):
• Range: up to 2500 A
• Resolution: 0.1 A (≤600 A); 1 A (≤2500 A)
• Accuracy: ±3% ±5 digits (5–500 Hz)
• Crest Factor: up to 3.0 at 1100 A; add 2% for crest >2 -
DC Current:
• Range: up to 600.0 A
• Resolution: 0.1 A
• Accuracy: ±2% ±5 digits -
AC Voltage:
• Range: up to 1000 V
• Resolution: 0.1 V (≤600 V); 1 V (≤1000 V)
• Accuracy: ±1.5% ±5 digits (20–500 Hz) -
DC Voltage:
• Range: up to 1000 V
• Resolution: 0.1 V (≤600 V); 1 V (≤1000 V)
• Accuracy: ±1% ±5 digits -
mV DC Input:
• Range: up to 500.0 mV
• Resolution: 0.1 mV
• Accuracy: ±1% ±5 digits -
Frequency (via jaw or iFlex):
• Range: 5.0–500.0 Hz
• Resolution: 0.1 Hz
• Accuracy: ±0.5% ±5 digits -
Resistance:
• Range: up to 60 kΩ
• Resolution: 0.1 Ω (≤600 Ω); 1 Ω (≤6000 Ω); 10 Ω (≤60 kΩ)
• Accuracy: ±1% ±5 digits -
Capacitance:
• Range: up to 1000 µF
• Resolution: 0.1 µF (≤100 µF); 1 µF (≤1000 µF)
• Accuracy: ±1% ±4 digits
🛠 Additional Features
-
True-RMS for accurate measurements on non-linear loads
-
Low-pass filter for measurements on variable-frequency drives
-
Inrush current capture for motor startup analysis
-
Min/Max/Avg recording and data hold
-
Compact and ergonomic design
-
Jaw opening: 34 mm
-
Optional iFlex flexible current probe for expanded measurement range and access
📦 Mechanical & Environmental Specs
-
Dimensions: 246 × 83 × 43 mm
-
Weight: Approx. 388 g
-
Jaw Opening: 34 mm
-
iFlex Cable Length: Approx. 1.8 m
-
Operating Temperature: –10 °C to +50 °C
-
Storage Temperature: –40 °C to +60 °C
-
Operating Humidity:
• ≤90% RH at 10–30 °C
• ≤75% RH at 30–40 °C
• ≤45% RH at 40–50 °C -
Altitude:
• Operating: up to 3000 m
• Storage: up to 12,000 m -
Safety Ratings:
• CAT III 1000 V
• CAT IV 600 V -
IP Rating: IP30 (when not operating)
✅ Quick Reference Table
Measurement Type | Range | Resolution | Accuracy |
---|---|---|---|
AC Current (jaw) | up to 600 A | 0.1 A | ±2% ±5 digits |
AC Current (iFlex) | up to 2500 A | 0.1–1 A | ±3% ±5 digits |
DC Current | up to 600 A | 0.1 A | ±2% ±5 digits |
AC Voltage | up to 1000 V | 0.1–1 V | ±1.5% ±5 digits |
DC Voltage | up to 1000 V | 0.1–1 V | ±1% ±5 digits |
mV DC | up to 500.0 mV | 0.1 mV | ±1% ±5 digits |
Resistance | up to 60 kΩ | varies | ±1% ±5 digits |
Capacitance | up to 1000 µF | 0.1–1 µF | ±1% ±4 digits |
Frequency | 5.0–500.0 Hz | 0.1 Hz | ±0.5% ±5 digits |