BOLD Industrial
Fluke 374 – True‑RMS AC/DC Clamp Meter
Couldn't load pickup availability
Fluke 374 – True‑RMS AC/DC Clamp Meter Specifications
⚡ Electrical Measurements
-
**AC Current (via jaw clamp)**
• Range: up to 600.0 A
• Resolution: 0.1 A
• Accuracy: ±2% ±5 digits (10–100 Hz), ±2.5% ±5 digits (100–500 Hz)
• Crest Factor: up to 2.5 at 600 A; add 2% for crest factor >2 -
AC Current (via optional iFlex flexible probe)
• Range: up to 2500 A
• Resolution: 0.1 A (≤ 600 A), 1 A (≤ 2500 A)
• Accuracy: ±3% ±5 digits (5–500 Hz)
• Crest Factor: up to 3.0 at 1400 A; add 2% for crest factor >2 -
Position Sensitivity (iFlex probe)
• Accuracy declines slightly when conductor is off-center (up to ±2% error depending on offset distances) -
DC Current (jaw)
• Range: up to 600.0 A
• Resolution: 0.1 A
• Accuracy: ±2% ±5 digits -
AC Voltage
• Range: up to 1000 V
• Resolution: 0.1 V (≤ 600 V), 1 V (≤ 1000 V)
• Accuracy: ±1.5% ±5 digits (20–500 Hz) -
DC Voltage
• Range: up to 1000 V
• Resolution: 0.1 V (≤ 600 V), 1 V (≤ 1000 V)
• Accuracy: ±1% ±5 digits -
mV DC Input
• Range: up to 500.0 mV
• Resolution: 0.1 mV
• Accuracy: ±1% ±5 digits -
Resistance
• Range: up to 6000 Ω
• Resolution: 0.1 Ω (≤ 600 Ω), 1 Ω (≤ 6000 Ω)
• Accuracy: ±1% ±5 digits -
Capacitance
• Range: up to 1000 µF
• Resolution: 0.1 µF (≤ 100 µF), 1 µF (≤ 1000 µF)
• Accuracy: ±1% ±4 digits -
Frequency (using clamp)
• Range: 5.0–500.0 Hz
• Resolution: 0.1 Hz
• Accuracy: ±0.5% ±5 digits
• Minimum trigger current varies by frequency band (e.g. ≥10 A at mid‑range)
🛠 Additional Features
-
True‑RMS capability ensures stable readings on non-sinusoidal waveforms
-
Filter mode to improve accuracy on variable-frequency drives (VFDs)
-
Inrush current capture records peak motor start-up values
-
Min/Max/Average data logging and data hold function
-
Ergonomically shaped with a 34 mm jaw; optional iFlex probe improves conductor access
📦 Mechanical & Environmental Information
-
Dimensions: approx. 249 × 85 × 45 mm
-
Weight: approx. 395 g
-
Jaw opening: 34 mm
-
iFlex probe cable (if used): 1.8 m long, 7.5 mm diameter
-
Operating temperature: –10 °C to +50 °C
-
Storage temperature: –40 °C to +60 °C
-
Operating humidity (non-condensing): up to 90% RH at 10–30 °C, 75% at 30–40 °C, 45% at 40–50 °C
-
Altitude limits: operates up to 3000 m; storage to 12,000 m
-
Safety category ratings:
• CAT III 1000 V / CAT IV 600 V
• Pollution degree 2 (per IEC 61010-1 / IEC 61010‑2‑032) -
Ingress protection: IP30 (when not operating)
✅ Quick Specs Table
Measurement Type | Range / Resolution | Accuracy |
---|---|---|
AC Current (jaw) | up to 600 A / 0.1 A | ±2–2.5% ±5 digits |
AC Current (iFlex) | up to 2500 A / 0.1–1 A | ±3% ±5 digits |
DC Current (jaw) | up to 600 A / 0.1 A | ±2% ±5 digits |
AC Voltage | up to 1000 V / 0.1–1 V | ±1.5% ±5 digits |
DC Voltage | up to 1000 V / 0.1–1 V | ±1% ±5 digits |
mV DC Input | up to 500 mV / 0.1 mV | ±1% ±5 digits |
Resistance | up to 6000 Ω / 0.1–1 Ω | ±1% ±5 digits |
Capacitance | up to 1000 µF / 0.1–1 µF | ±1% ±4 digits |
Frequency (clamp) | 5–500 Hz / 0.1 Hz | ±0.5% ±5 digits |