Fluke 374 – True‑RMS AC/DC Clamp Meter Specifications

⚡ Electrical Measurements

  • **AC Current (via jaw clamp)**
    • Range: up to 600.0 A
    • Resolution: 0.1 A
    • Accuracy: ±2% ±5 digits (10–100 Hz), ±2.5% ±5 digits (100–500 Hz)
    • Crest Factor: up to 2.5 at 600 A; add 2% for crest factor >2

  • AC Current (via optional iFlex flexible probe)
    • Range: up to 2500 A
    • Resolution: 0.1 A (≤ 600 A), 1 A (≤ 2500 A)
    • Accuracy: ±3% ±5 digits (5–500 Hz)
    • Crest Factor: up to 3.0 at 1400 A; add 2% for crest factor >2

  • Position Sensitivity (iFlex probe)
    • Accuracy declines slightly when conductor is off-center (up to ±2% error depending on offset distances)

  • DC Current (jaw)
    • Range: up to 600.0 A
    • Resolution: 0.1 A
    • Accuracy: ±2% ±5 digits

  • AC Voltage
    • Range: up to 1000 V
    • Resolution: 0.1 V (≤ 600 V), 1 V (≤ 1000 V)
    • Accuracy: ±1.5% ±5 digits (20–500 Hz)

  • DC Voltage
    • Range: up to 1000 V
    • Resolution: 0.1 V (≤ 600 V), 1 V (≤ 1000 V)
    • Accuracy: ±1% ±5 digits

  • mV DC Input
    • Range: up to 500.0 mV
    • Resolution: 0.1 mV
    • Accuracy: ±1% ±5 digits

  • Resistance
    • Range: up to 6000 Ω
    • Resolution: 0.1 Ω (≤ 600 Ω), 1 Ω (≤ 6000 Ω)
    • Accuracy: ±1% ±5 digits

  • Capacitance
    • Range: up to 1000 µF
    • Resolution: 0.1 µF (≤ 100 µF), 1 µF (≤ 1000 µF)
    • Accuracy: ±1% ±4 digits

  • Frequency (using clamp)
    • Range: 5.0–500.0 Hz
    • Resolution: 0.1 Hz
    • Accuracy: ±0.5% ±5 digits
    • Minimum trigger current varies by frequency band (e.g. ≥10 A at mid‑range)


🛠 Additional Features

  • True‑RMS capability ensures stable readings on non-sinusoidal waveforms

  • Filter mode to improve accuracy on variable-frequency drives (VFDs)

  • Inrush current capture records peak motor start-up values

  • Min/Max/Average data logging and data hold function

  • Ergonomically shaped with a 34 mm jaw; optional iFlex probe improves conductor access


📦 Mechanical & Environmental Information

  • Dimensions: approx. 249 × 85 × 45 mm

  • Weight: approx. 395 g

  • Jaw opening: 34 mm

  • iFlex probe cable (if used): 1.8 m long, 7.5 mm diameter

  • Operating temperature: –10 °C to +50 °C

  • Storage temperature: –40 °C to +60 °C

  • Operating humidity (non-condensing): up to 90% RH at 10–30 °C, 75% at 30–40 °C, 45% at 40–50 °C

  • Altitude limits: operates up to 3000 m; storage to 12,000 m

  • Safety category ratings:
    • CAT III 1000 V / CAT IV 600 V
    • Pollution degree 2 (per IEC 61010-1 / IEC 61010‑2‑032)

  • Ingress protection: IP30 (when not operating)


✅ Quick Specs Table

Measurement Type Range / Resolution Accuracy
AC Current (jaw) up to 600 A / 0.1 A ±2–2.5% ±5 digits
AC Current (iFlex) up to 2500 A / 0.1–1 A ±3% ±5 digits
DC Current (jaw) up to 600 A / 0.1 A ±2% ±5 digits
AC Voltage up to 1000 V / 0.1–1 V ±1.5% ±5 digits
DC Voltage up to 1000 V / 0.1–1 V ±1% ±5 digits
mV DC Input up to 500 mV / 0.1 mV ±1% ±5 digits
Resistance up to 6000 Ω / 0.1–1 Ω ±1% ±5 digits
Capacitance up to 1000 µF / 0.1–1 µF ±1% ±4 digits
Frequency (clamp) 5–500 Hz / 0.1 Hz ±0.5% ±5 digits